CHEMICAL BOLT M16x190 GRADE 5.8
- Product code: BLHC58M16x190
M16x190 chemical bolts with durability level 5.8 consist of 2 main parts: the M16x190 bolt part and the chemical part. The product is used in installing column legs, installing steel beams, installing emergency stairs, installing lobby roofs (canopy roofs),...
-
578
-
Contact us
DESCRIPTION OF CHEMICAL BOLT M16x190 GRADE 5.8:
M16x190 chemical bolts, grade 5.8, consist of 2 main parts
The M16x190 bolt part includes a 16mm diameter bolt body, 190m long + 1 ecu + 1 flat black washer, black warping washer can be added upon request. The bolt body usually has a hexagonal head, the other end is cut into a V shape and has a notch in the middle. Electrolytic galvanized bolts have a durability level of 5.8
Chemical section. You can use chemicals in bottle form using a pump gun or M16 capsule chemicals
APPLICATIONS OF CHEMICAL BOLT M16x190 GRADE 5.8:
Install railings
Installing glass facades and stone facades
Install steel column legs and steel beams
Install canopy roof. Roof lobby
Install emergency stairs
Install ventilation fans
Fix the foot of the shelf.
Fixing pipes in high-rise buildings or factories, hospitals, schools,...
Install the tripod
CONSTRUCTION OPERATION OF CHEMICAL BOLT M16x190 GRADE 5.8:
Step 1: Drill an 18mm hole, 125mm deep in the concrete
Step 2: Use a brush and dust blower to clean the bore
Step 3: Pump chemicals into the borehole (If the chemical is in bottle form, use a pump gun) or place the capsule into the borehole (if the chemical is in capsule form)
Step 4: Insert the threaded rod into the drill hole so that the chemical flows out to the mouth (If the chemical is in bottle form, use a pump gun) or drill the threaded rod to break the capsule (If using chemicals in capsule form. The threaded rod is connected to the drill via a connection tool and drilled to break the capsule)
Step 5: Wait for the chemical to set and then install the load. Normally, if you use capsule chemicals, the time for the chemicals to set to maximum load is 30-45 minutes. If you use epoxy chemicals in bottle form using a pump gun, the average time to reach maximum load is 8 hours.
SPECIFICATIONS OF CHEMICAL BOLT FORCE M16X190 GRADE 5.8:
Traction force: 30KN corresponding to a weight of 3 tons
Cutting force: 30KN corresponding to a weight of 3 tons
The above parameters are recommended when used with C20/25 basic concrete
Share: